I-BS-2082F Research Fluorescent Biological Microscope

Ngemva kweminyaka yocwaningo nentuthuko emkhakheni wezobuchwepheshe obubonakalayo, isibonakhulu se-BS-2082F sebhayoloji yakhelwe ukwethula ukuzizwisa okuphephile, okunethezekile kanye nokusebenza kahle kwabasebenzisi.Ngesakhiwo esenziwe kahle, isithombe sokubonwa esiphezulu esinencazelo ephezulu kanye nesistimu yokusebenza elula, i-BS-2082F ibona ukuhlaziya kochwepheshe, futhi ihlangabezana nazo zonke izidingo zocwaningo kwezesayensi, zezokwelapha neminye imikhakha.


Imininingwane Yomkhiqizo

Landa

Ikhwalithi yokulawula

Omaka bomkhiqizo

I-BS-2082F Research Biological Microscope

I-BS-2082F

Isingeniso

Ngemva kweminyaka yocwaningo nentuthuko emkhakheni wezobuchwepheshe obubonakalayo, isibonakhulu se-BS-2082 sebhayoloji yakhelwe ukwethula ukuzizwisa okuphephile, okunethezekile kanye nokusebenza kahle kwabasebenzisi.Ngesakhiwo esenziwe kahle, isithombe sokubonwa esiphezulu esinencazelo ephezulu kanye nesistimu yokusebenza elula, i-BS-2082 ibona ukuhlaziya kochwepheshe, futhi ihlangabezana nazo zonke izidingo zocwaningo kwezesayensi, zezokwelapha neminye imikhakha.

Isici

I-BS-2082 Research Biological Microscope Eyepiece

I-eyepiece ye-eye point yensimu ebanzi yohlelo lweso.

Inkundla yokubuka ye-eyepiece iye yathuthukiswa isuka ku-22mm evamile yaya ku-25mm kanye ne-26.5mm, inikeza indawo yokubuka eyisicaba futhi ithuthukisa ukusebenza kahle.Ngebanga elibanzi lokulungiswa kwe-diopter kanye ne-eye guard yerabha egoqekayo.

Ikhanda elibuka elinesilinganiso sokuhlukaniswa okuningi.

Ikhanda lokubuka lenzelwe izinketho eziningi zokuhlukanisa isilinganiso.
(1) Ikhanda elingunxantathu elinesithombe esihlanekezelwe, isilinganiso sokuhlukanisa I-Binocular: Trinocular=100:0 noma 20:80 noma 0:100 ijwayelekile.Ngaphandle kokugxilisa ukukhanya okungu-100% kushubhu ye-eyepiece noma ishubhu yekhamera, kukhona enye inketho enokukhanya okungu-20% kuya kushubhu ye-eyepiece kanye no-80% kushubhu yekhamera, ukuze ukubhekwa kwe-eyepiece nokukhipha isithombe kutholakale ngesikhathi esifanayo.
(2) Ikhanda elingunxantathu elinesithombe esimisiwe, isilinganiso sokuhlukanisa I-Binocular:Trinocular=100:0 noma 0:100 uyazikhethela.Indlela enyakazayo yamasampula iyafana nebonwayo.

Inhloko ye-BS-2082 Research Biological Microscope

Usayizi omkhulu rackless isigaba izandla zombili.

Isiteji esikhulu esilungiswayo kunoma yisiphi isandla Ukuze kulungiswe ingozi efihlekile yesitimela somkhathizwe, isiteji siklanywe ngendlela yokushayela enezinhlangothi ezimbili.Lolu shintsho luvikela isiteji ekulayisheni ngokweqile ekugcineni komzila womzila womabili, kuthuthukisa ukwethembeka nokusebenza kwesiteji.

Isibambo sesiteji singasethwa ohlangothini ngalunye ngokusekelwe kokuthandwa ngabasebenzisi.I-X, Y ukulungiswa kwe-biaxial yakhelwe ngendlela ephansi ukuze isebenze ngokunethezeka.

Izingcezu ezimbili zingabanjwa esiteji ngokusebenzisa iziqeshana eziphindwe kabili zohlobo lwe-damping, okulula ukufunda ngokuqhathanisa.Ibanga elihambayo: 80mm X55mm;ukunemba: 0.1mm.Icutshungulwe ngobuciko obukhethekile, ingaphezulu lesiteji liyi-anti-corrosive kanye ne-anti-friction.Iplathifomu ene-arc transition design inciphisa ukugxilisa ingqondo nokulimala okuvela kumthelela.

I-BS-2082 Research Biological Microscope Stage

Uhlaka lwe-Modular, thuthukisa ukuhambisana kwesistimu.

Ngomklamo we-modularization, ingalo ehlukanisiwe ehlukanisiwe nomzimba oyinhloko, ithuthukisa ukuhambisana kwesistimu yohlaka lwebhayoloji nolwe-fluorescence.

I-coaxial ebucayi kakhulu nesistimu yokulungiswa okuhle.

Ukulungiswa kwe-coaxial kusebenzisa izigaba ezimbili zokushayela, ngokuqina kokuqina okuguquguqukayo kanye nokuma komkhawulo ongaphezulu, ububanzi obumaholo bungu-25mm nokunemba okuhle kungu-1μm.Akukhona nje kuphela ukugxila ngokunembile kodwa futhi nesilinganiso sokunemba siyatholakala.

img

Isicelo

Lesi sibonakhulu siyithuluzi elikahle ku-biology, histological, pathological, bacteriology, imigomo kanye nenkundla yekhemisi futhi ingasetshenziswa kabanzi ezikhungweni zezokwelapha nezokuhlanzeka, amalabhorethri, izikhungo, amalabhorethri ezemfundo, amakolishi namanyuvesi.

Ukucaciswa

Into

Ukucaciswa

BS-2082

I-BS-2082F

BS-2082

MH10

Isistimu ye-Optical Umbala ongapheli ulungise isistimu yokubona

Inhloko Ebukayo Ikhanda le-Seidentopf trinocular(Isithombe esihlanekezelwe), 30° ethambekele, ibanga le-interpupillary: 50mm-76mm;isilinganiso sokuhlukanisa i-Eyepiece:Trinocular=100:0 noma 20:80 noma 0:100

Ikhanda le-Seidentopf trinocular(Isithombe esimisiwe), 30° ethambekele, ibanga le-interpupillary: 50mm-76mm;ukuhlukanisa isilinganiso I-Eyepiece:Trinocular=100:0 noma 0:100

Isiqephu samehlo I-eyepoint yensimu ebanzi yohlelo lwe-eyepiece ye-PL10X/25mm, i-diopter iyalungiseka

I-eyepiece ephezulu yensimu ebanzi ye-eyepiece PL10X/25mm, ene-reticle, i-diopter eguquguqukayo

I-eyepoint yensimu ebanzi yohlelo lwe-eyepiece PL10X/26.5mm, i-diopter iyalungiseka

I-eyepiece ephezulu yensimu ebanzi ye-eyepiece PL10X/26.5mm, ene-reticle, i-diopter eguquguqukayo

Inhloso Hlela inhloso ye-semi-apochromatic fluorescent 4X/0.13(infinity), WD=18.5mm

Hlela inhloso ye-semi-apochromatic fluorescent 10X/0.30(infinity), WD=10.6mm

Hlela inhloso ye-semi-apochromatic fluorescent 20X/0.50(infinity), WD=2.33mm

Hlela inhloso ye-semi-apochromatic fluorescent 40X/0.75(infinity), WD=0.6mm

Hlela inhloso ye-semi-apochromatic fluorescent 100X/1.30(infinity), WD=0.21mm

Ikhala (ene-DIC slot) I-backward Quintuple Nosepiece

I-backward Sextuple Nosepiece

I-backward Septuple nosepiece

Uhlaka Uhlaka lwebhayoloji (oludluliselwe), indawo ephansi ye-coaxial coarse nokulungiswa okuhle, ibanga lokulungisa elimahhadla: 25mm;ukunemba okuhle: 0.001mm.Ngokumiswa kokulungiswa okumahhadla nokulungiswa kokuqina.
I-voltage engu-100-240/60Hz eyakhelwe ngaphakathi engu-100-240V_AC50/60Hz i-voltage ebanzi yesiguquli, amandla angalungiseka ngokusetha kwedijithali nokusetha kabusha;izihlungi ezakhelwe ngaphakathi ze-LBD/ND6/ND25)

Uhlaka lwe-fluorescence (oludlulisiwe), indawo ephansi ye-coaxial coarse nokulungiswa okuhle, ibanga lokulungisa elimahhadla: 25mm;ukunemba okuhle: 0.001mm.Ngokumiswa kokulungiswa okumahhadla nokulungiswa kokuqina.
I-voltage engu-100-240/60Hz eyakhelwe ngaphakathi engu-100-240V_AC50/60Hz i-voltage ebanzi yesiguquli, amandla angalungiseka ngokusetha kwedijithali nokusetha kabusha;izihlungi ezakhelwe ngaphakathi ze-LBD/ND6/ND25)

Isiteji Isiteji somshini wezigaba ezimbili, usayizi: 187mm X168mm;ezihambayo ububanzi: 80mm X55mm;ukunemba: 0.1mm;idrayivu yomugqa wezindlela ezimbili, ukungezwani kuyalungiseka

I-Condenser I-Swing-out yohlobo lwe-achromatic condenser (NA0.9)

Isibani se-fluorescence esibonisiwe Isikhanyisi se-fluorescence esibonisiwe esine-iris field diaphragm kanye ne-aperture diaphragm, engakwazi ukulungiseka maphakathi;nge-slot yokuhlunga kanye ne-polarizing slot;ngezihlungi ze-fluorescence (UV/B/G ngokukhethwa kukho).

Indlu yesibani se-mercury engu-100W, isikhungo se-filament kanye nokugxila okulungisekayo;ngesibuko esibonisiwe, isikhungo sesibuko kanye nokugxila okulungisekayo.(75W xenon indlu yesibani ongakhetha kukho)

Isilawuli samandla edijithali, i-voltage ebanzi 100-240VAC

Isibani semercury se-OSRAM 100W esingenisiwe.( I-OSRAM 75W xenon isibani ongasikhetha)

Ukukhanyisa Okudlulisiwe I-12V/100W indlu yesibani se-halogen yokukhanya okudlulisiwe, isikhungo esethiwe ngaphambili, ukuqina kuyalungiseka

Ezinye Izinsiza I-adaptha yekhamera: 0.5X/0.65X/1X egxile ku-C-mount

Ikhamera ye-CCD epholile, i-SONY 2/3′′, 1.4MP, ICX285AQ Color CCD

Inhloso yokubeka maphakathi kokubhekwa kwe-fluorescence

Isilayidi sokulinganisa 0.01mm

Okunamathiselwe kokubuka okuningi kwabantu abangu-5

Okunamathiselwe kwi-imeyili kwe-DIC

Qaphela: ● Impahla Ejwayelekile, ○ Ongakukhetha

Isampula Izithombe

2082 (2)
2082 (1)

Isitifiketi

mhg

Logistics

isithombe (3)

  • Okwedlule:
  • Olandelayo:

  • I-BS-2082 Series Research Biological Microscope

    isithombe (1) isithombe (2)

    Bhala umyalezo wakho lapha futhi usithumelele wona